School of Biotechnology · Bioprocess & analytical

Analytical Techniques: Spectroscopy, Chromatography & HPLC

Analytical techniques decide whether a sample is what it claims to be and how much of it there is. This course teaches the core spectroscopic and chromatographic methods used in pharmaceutical, food and biotech laboratories.

Wet labIntermediate4 days · 24 hours at the bench · customisableCertificate with verification ID
Reversed-phase HPLC chromatogram (UV absorbance): the solvent front and five resolved peaks labelled by retention time. Peak area, not height, is used for quantification.

Course overview

Analytical Techniques covers UV–Vis spectroscopy, thin-layer and column chromatography, and the practical operation of an HPLC system: mobile phases, columns, detectors and integration.

You build calibration curves, run system-suitability tests and learn the ICH principles of method validation (specificity, linearity, accuracy, precision and robustness) used in regulated laboratories.

LevelIntermediate
DisciplineWet lab
Duration4 days · customisable
Guided hours24 h
FormatsIn-person, hands-on
Fee from₹14,499 + GST

Learning outcomes

By the end of the course you will be able to:

  1. Perform quantitative UV–Vis analysis with calibration
  2. Separate compounds by TLC and column chromatography
  3. Operate an HPLC system and integrate chromatograms
  4. Run system-suitability tests
  5. Apply ICH method-validation parameters

Skills you will practise

UV–Vis spectroscopyTLCColumn chromatographyHPLC operationCalibrationMethod validation

Eligibility and prerequisites

Who can apply

  • Students and graduates of B.Sc., M.Sc., B.Tech., M.Tech., B.Pharm., M.Pharm. or a PhD programme in biotechnology, microbiology, biochemistry, molecular biology, genetics, life sciences, pharmacy or allied health sciences
  • Laboratory staff, research assistants and faculty who want structured bench training
  • Participants must be 18 or older and follow the laboratory safety induction on day one

Prerequisites

  • Undergraduate chemistry

Best suited to

  • Students of pharmacy, biotechnology, chemistry and food science
  • Graduates aiming at QC and analytical roles
  • Researchers who need quantitative analysis

Module-wise syllabus

5 modules, each with a bench practical performed by every participant.

Topics

  • UV–Vis principles
  • Calibration and linearity
  • Sources of error
Bench practical 1Quantify an analyte by UV–Vis with a calibration curve.

Topics

  • TLC and Rf values
  • Column chromatography
  • Fraction analysis
Bench practical 2Separate a mixture by TLC and column chromatography and analyse fractions.

Topics

  • Pumps, columns and detectors
  • Mobile phases and gradients
  • Peak integration
Bench practical 3Run standards on an HPLC system and integrate the chromatograms.

Topics

  • External-standard calibration
  • System-suitability parameters
  • Troubleshooting
Bench practical 4Quantify an analyte in samples and evaluate system suitability.

Topics

  • ICH Q2 parameters
  • Robustness
  • Documentation
Bench practical 5Plan and partially execute a validation for the HPLC method.

Practical sessions and projects

Practical assessment

Practical assessment

Quantify an analyte by HPLC with calibration and system suitability, and present a validation plan.

Assessed on technique, accuracy, safety and the laboratory record. A pass is required for the certificate.

  1. Spectroscopy

    Quantify an analyte by UV–Vis with a calibration curve.

  2. Planar and column chromatography

    Separate a mixture by TLC and column chromatography and analyse fractions.

  3. HPLC fundamentals

    Run standards on an HPLC system and integrate the chromatograms.

  4. Quantification and suitability

    Quantify an analyte in samples and evaluate system suitability.

  5. Method validation

    Plan and partially execute a validation for the HPLC method.

Instruments, techniques and materials

Instruments and equipment

HPLC system with UV detectorUV–Vis spectrophotometerTLC equipmentChromatography columnsAnalytical balance

Techniques you will perform

  • UV–Vis quantification
  • TLC
  • Column chromatography
  • Reversed-phase HPLC
  • System suitability
  • Validation experiments

Materials

  • Analytical standards
  • HPLC-grade solvents
  • Columns and consumables

Core reading

  • Snyder LR, Kirkland JJ, Dolan JW. Introduction to Modern Liquid Chromatography, 3rd edition. Wiley, 2010.
  • ICH Q2(R2): Validation of Analytical Procedures (current guideline).

Duration, format and fees

Flexible duration. Duration is customisable: run the bench days back to back, or spread them over weekends within 4 weeks. Colleges and teams can book their own dates.
Next cohort
Dates are sent with your admission offer
Timetable
Weekdays, 9:30 to 16:30, at our laboratory
Payment
Secure online payment link with your admission offer (UPI, cards, net banking). Instalments on request for fees above ₹15,000.

Instructor

The instructor for each cohort is named in your admission offer and on this page when the cohort is announced. Vedicgen instructors are selected for hands-on laboratory experience in the subject they teach, and every course is reviewed by a second subject expert.

Questions about who teaches a cohort? [email protected]

Certificate

Learners who complete the course and pass its practical assessment receive a Vedicgen certificate of completion for Analytical Techniques: Spectroscopy, Chromatography & HPLC, issued by Vivofold, stating the bench hours and techniques performed. Each certificate has a unique ID and QR code that anyone can check.

Verify a certificate

Certificate of completionSample
Analytical Techniques: Spectroscopy, Chromatography & HPLCAwarded to the learner named on the certificate · 24 hours
ID · VG-XXXX-XXXXVivofold Vedicgen

Apply for Analytical Techniques: Spectroscopy, Chromatography & HPLC

  1. Apply

    Send the form below. It takes about five minutes.

  2. Review

    An adviser confirms your fit and format within two working days.

  3. Offer

    You receive dates, timetable and a secure payment link.

  4. Onboard

    Safety briefing, lab address and joining instructions.

About you

Education

Programme

Your goalsA few lines help us advise you well.

0/40+ characters
Sent securely to [email protected]. Your details are used only to process this request.

Frequently asked questions

Yes. Day one starts with a safety induction covering personal protective equipment, safe handling of reagents and biological material, spill response and waste segregation. All practicals use non-pathogenic material (Risk Group 1 organisms, established cell lines or synthetic templates) and are supervised throughout.

All reagents, kits, consumables, personal protective equipment, the lab manual and the certificate. Travel, accommodation and meals are not included. The laboratory address and joining instructions are sent with your admission letter.

Bench courses run in small groups so that every participant performs every practical personally, with an instructor-to-participant ratio that allows close supervision at the bench.

Yes. Learners who complete the course and pass its assessment receive a Vedicgen certificate of completion, issued by Vivofold. Every certificate carries a unique ID and a QR code that anyone, including an employer or admissions office, can check on the certificate verification page.

Apply with the form on this page. Live and in-person cohorts run through the year; the dates, timetable and joining details of the next cohort are sent with your admission offer and listed on this page once announced. Self-paced enrolment opens as soon as your application is accepted.

Yes. No course runs longer than four weeks, and the length is customisable: choose the standard schedule, an intensive one- to two-week schedule, weekends only, or a custom timetable. Pick your preference on the application form; colleges and teams can book their own dates.